New TIPIX Master-Slave mode

IRIS Instruments is proud to announce the new Master-Slave mode ability on old and new TIPIX systems (TIPIX 2200 and 3000).



The MASTER-SLAVE mode allows to connect two TIPIX in series, whatever their power. This type of connection adds the maximum voltage and power of the two systems to increase the amount of current injected on medium to high contact resistance values. 
As an example, two TIPIX 3000 connected in series are able to work at 5000 V (10000 Vpp) and 6kW power. Read our brochure for more information.

The use of the MASTER-SLAVE mode is very easy as it is automatically recognized and the combined system maximum voltage and power is automatically updated. The two TIPIX can be powered by a single motor generator making the complete system light and portable

Contact us if you want to add this option to your TIPIX.

TIPIX



Multiple TIPIX in synchronized emission to :

1) increase injection level by combining several TIPIX all synchronized on a GPS PPS

2) speed up resistivity and chargeability measurements by injecting and measuring simultaneously in distant areas with limited disruption on the signal.

TIPIX



TIPIX major benefits
  • TIPIX is a 3 kW transmitter designed for IP surveys and for deep resistivity soundings. 
  • It is microprocessor controlled for ease of operation and protection against misuse. 
  • A four line alphanumeric display is provided for the simultaneous indication of all output parameters: output current, output voltage, contact resistance and output power are continuously displayed 
  • A standard motor generator can be used to power the TIPIX 


TIPIX main features
  • The TIPIX will generate up to 2 400 volts for work in high resistivity areas and up to 13 amperes for low resistivity regions. 
  • The TIPIX is designed for ease of operation. Four buttons on the front panel are used to select the desired options and to increase or decrease the current. 
  • Limit values of voltage, current or power can be introduced. 
  • Messages and warnings are displayed in case of problem or malfunction, for an easier identification of a trouble and a quicker instrument servicing.
  • Controlled by GPS for precise timing and multiple tx used.

Price and availability, contact us : sales@iris-instruments.com